BFZCC - 604 ANTI RUST SPRAY, 34727(NEW FORMULATION)

  • MSDS: BFZCC
  • Manufacturer: SPRAYON PRODUCTS
  • Product Name: 604 ANTI RUST SPRAY, 34727(NEW FORMULATION)
  • National Stock Number: 8030-00-957-3089
Product Identification

Product ID:604 ANTI RUST SPRAY, 34727(NEW FORMULATION)
MSDS Date:01/01/1987
FSC:8030
NIIN:00-957-3089
MSDS Number: BFZCC

Responsible Party
SPRAYON PRODUCTS
26300 FARGO AVE
BEDFORD HEIGHTS, OH 44146-1310
US

Emergency Phone: 216-292-7400

Cage: 09800

Contractor
SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
BEDFORD HEIGHTS, OH 44146 US

Telephone: 216-292-7400 OR 216-595-8634

Cage: 09800

Ingredients

ODORLESS MINERAL SPIRITS (CAS# 64742-89-8) (LEL=1.1)

Fraction By Weight: 55%

ACGIH TLV: 500 PPM (MFR)


2-BUTOXYETHANOL

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: 5 - 15%

OSHA PEL S, 50 PPM

ACGIH TLV: S, 25 PPM; 9293


ISOBUTANE (CAS# 75-28-5) (LEL=1.8)

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 10%

ACGIH TLV: 1000 PPM (MFR)


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 10 - 23%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9192

Hazards

Effects of Overexposure:HIGH VAP CONC IN CONF AREA IS
ANESTHETIC.SKIN,UPPER RESP SYS IRRIT.POSS LIGHT-HEAD,(SEE OTHR
PRECAUT

First Aid

First Aid:EYES:FLUSH W/H*2O FOR @ LEAST 15 MIN. SKIN:WASH W/SOAP &
H*2O. INHAL:REMOVE PATIENT TO FRESH AIR. INGEST:CALL DR
IMMEDIATELY. DO NOT INDUCE VOMITING.

Fire Fighting

Flash Point:PRPLNT < 20F,TOC
Extinguishing Media:CO*2,DRY CHEMICAL OR FOAM
Fire Fighting Procedures:NIOSH/MSHA APPROVED SCBA,FULL PROT
EQUIP.DONT(SEE SUPP DATA)
Unusual Fire/Explosion Hazard:H*2O POSS INEFFECTIVE,MAY BE USED TO KEEP
FIRE EXPOSED CONTAINERS COOL.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION,VENTILATE.
AVOID BREATHING VAPORS & REMOVE W/INERT ABSORBENT.

Handling

Handling and Storage Precautions:KEEP AWAY FROM CHILDREN. DO NOT
PUNCTURE OR INCINERATE. DO NOT SPRAY NEAR FIRE OR OPEN FLAME.
Other Precautions:EFTS OF OVEREXP:STAGGERING,GIDDY,POSS
NAUS.HARMFUL/FATAL IF INGEST.REPORTS ASSOCIATE RPTD/PRLNG OVEREXP
TO SOLVENTS W/PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE.REFORMULATION
OCCURED BEFORE 7-77.

Exposure Controls

Ventilation:LOCAL EXHAUST VENT TO KEEP BELOW ACCEPTABLE TLV.
Protective Gloves:PRLNG/RPTD CONT
Eye Protection:CHEMICAL WORKERS GOGGLES
Supplemental Safety and Health
EVAPORATION RATE IS FOR PROPELLANT. % VOLATILE BY WT:85. SPECIAL FIRE
FIGHT PROC:SPRAY NEAR OPEN FLM. KEEP @ ROOM TEMP;HEAT MAY CAUSE
BURSTING. DATE OF PREP:3-22-86.

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:PRPLT <0.0F
Vapor Density:> 1
Evaporation Rate & Reference:FASTER THAN ETHER

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:DO NOT STORE ABOVE 120F.
Hazardous Decomposition Products:BY OPEN FLM:CO,CO*2

Disposal

Waste Disposal Methods:DO NOT INCINERATE. DISPOSE OF IN ACCORDANCE WITH
FEDERAL,STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.